Flanged Joint Consultancy
What We Do
Rich Ergon provides Comprehensive Flanged Joint Consultancy Services.
-
Bespoke Solutions for Problematic Joints
-
Joint Integrity Management
-
Industrial Gasket Supply and more

We work together with our clients to curate and maintain their Joint Integrity needs with our
0%
Break
Done: 3,743
Pending: 0
Pending: 0
0%
Box-up
Done: 3,743
Pending: 0
Pending: 0
0%
Completed
Done: 3,743
Pending: 0
Pending: 0
Flange Assurance Management

Design and Execute Joint Integrity Program

Joint Defect Inspection and Reporting

Manpower Competency Assessment
Joint Leak Investigation & Analysis
Advanced Analysis with Finite Element Modelling
Joint Leak Investigation & Analysis
Advanced Analysis with Finite Element Modelling
Leak manifested immediately after startup due to load loss caused by Channel Head weight (after re-boring)
SITE OBSERVATIONS / EVIDENCES:
LEAKING IN YEAR 2008, 2014 & 2017 (Immediately after Start Up)
- All without tapped hole (re-boring completed)
- Leak consistently occurred at Column side, at 12 o’clock position. Suggesting it is due to weight of Channel Head
- Unable to arrest leak even with further tightening
Â
Deformation of EB 221&EB 224 joints under Channel Head weight loading
Â
Zero contact pressures of EB 221 & EB 224 gasket at 12 o’clock position under Channel Head weight loading