Flanged Joint Consultancy

What We Do

Rich Ergon provides Comprehensive Flanged Joint Consultancy Services.

  • Bespoke Solutions for Problematic Joints

  • Joint Integrity Management

  • Industrial Gasket Supply and more

We work together with our clients to curate and maintain their Joint Integrity needs with our Cloud Base Flange Digital Database (JUICE).

0%
Break
Done: 3,743
Pending: 0
0%
Box-up
Done: 3,743
Pending: 0
0%
Completed
Done: 3,743
Pending: 0

Flange Assurance Management

Design and Execute Joint Integrity Program

Joint Defect Inspection and Reporting

Manpower Competency Assessment

Leak manifested immediately after startup due to load loss caused by Channel Head weight (after re-boring)

SITE OBSERVATIONS / EVIDENCES:

LEAKING IN YEAR 2008, 2014 & 2017 (Immediately after Start Up)

  1. All without tapped hole (re-boring completed)
  2. Leak consistently occurred at Column side, at 12 o’clock position. Suggesting it is due to weight of Channel Head
  3. Unable to arrest leak even with further tightening

 

Deformation of EB 221&EB 224 joints under Channel Head weight loading

 

Zero contact pressures of EB 221 & EB 224 gasket at 12 o’clock position under Channel Head weight loading